8D Problem Definition: Use Is/Is Not Before 5 Why
Why root cause analysis starts before the first “why”
A machine produces a defect, a customer rejects a shipment, or an inspection result moves outside specification. The team opens an 8D and immediately asks why it happened.
That urgency is understandable. But if the starting statement is “poor assembly quality,” each person may investigate a different problem. Maintenance looks for equipment faults, production focuses on handling, and quality reviews inspection performance. Their work may be competent, yet poorly aligned.
In 8D, D2 establishes a measurable description of the problem. It should identify the affected object, the specific deviation, and the boundaries of the available evidence. A useful problem definition does not explain the cause. It makes the question precise enough to investigate.
Is/Is Not analysis helps build that definition before the team uses 5 Why or an Ishikawa diagram.
What belongs in an 8D problem statement?
A practical problem statement separates observed facts from interpretations. Start with these elements:
- Object: Which product, component, process output, or characteristic is affected?
- Deviation: What requirement is not being met?
- Location: Where on the product and where in the process was it observed?
- Timing: When was it first detected, and during which production periods?
- Extent: How many units were affected out of how many examined?
- Evidence source: Which inspection records, measurements, or samples support the description?
Include the specification or acceptance criterion when available. “Excessive diameter” is less useful than a measured range compared with a defined upper limit.
Also distinguish the point of detection from the point of occurrence. Finding a scratch at final inspection does not establish that final inspection caused it—or that it originated at the previous operation.
An RCA and 8D workspace can help organize the investigation, but the team still needs a clear distinction between evidence, hypotheses, and unanswered questions.
Avoid embedding a suspected cause
Compare these two statements:
- “Incorrect setup caused oversized bores.”
- “Bores on part P-214 exceeded the upper diameter limit in samples collected from machining center MC-03 during the night shift.”
The first statement assumes the conclusion. The second identifies an observable deviation while leaving setup, tooling, measurement, and other explanations open for investigation.
If setup is suspected, record it separately as a hypothesis with the evidence needed to test it.
Build an Is/Is Not comparison
Is/Is Not analysis compares the observed problem with relevant situations where the same problem could reasonably occur but has not been observed.
The comparison is useful because a plausible explanation should account for both sides: why the deviation appears in one population and not in a closely related population.
What “Is” means
The “Is” side contains confirmed observations:
- The affected part number or product family.
- The specific defect or failed characteristic.
- The machine, cavity, station, or production route involved.
- The production and detection time windows.
- The observed frequency and measured severity.
Use traceable records rather than recollections wherever possible. If timestamps or lot genealogy are incomplete, mark the uncertainty rather than filling the gap with assumptions.
What “Is Not” means
The “Is Not” side identifies meaningful comparisons. Examples include the same part on another machine, adjacent cavities in the same mold, or earlier production made under comparable conditions.
An unrelated product from another process is usually a weak comparison. The most useful contrasts share many conditions with the affected population but differ in a few identifiable ways.
“No defects reported” is not equivalent to “no defects found using a suitable inspection.” Record the sample size, inspection method, and time window behind negative findings. Where inspection has not occurred, label the condition unknown, not unaffected.
Practical example: intermittent leakage after assembly
Consider an illustrative case involving a valve assembly. Final testing detects external leakage on some units. The initial complaint is: “Assembly is damaging seals.”
That description contains an unverified cause. The team replaces it with a factual statement:
During final testing on 14 May, 18 of 240 valve assemblies from line A exceeded the external leakage limit of 2 standard cubic centimeters per minute at 6 bar. Leakage was localized to the body-cover interface. The time of defect introduction is not yet known.
The team then builds its comparison:
| Dimension | Is | Is Not / comparison | |---|---|---| | Product | Valve model V-40 | No failures found in 120 V-40 units tested from line B that day | | Location | Body-cover interface | No leakage detected at the port connections on the failed units | | Timing | Units assembled after the morning changeover | No failures found in the retained sample of 40 units assembled before changeover | | Route | Line A assembly route | Line B route, using the same final-test procedure | | Material | Seal lot S-118 used on affected units | Unknown whether other seal lots show the same behavior |
These observations narrow the investigation without proving a cause. The before-and-after distinction makes changeover records relevant. The line comparison makes equipment, fixtures, and assembly conditions worth examining. The seal lot remains a possible factor, but its role is unresolved.
Before comparing failure rates, the team checks that both test stations use the same approved parameters and have acceptable measurement performance. Otherwise, an apparent process difference could be a detection difference.
The problem definition also informs containment. The team considers potentially affected production and shipped stock based on traceability and risk—not just the 18 units already known to fail.
Move from contrasts to Ishikawa and 5 Why
Once the problem boundaries are clear, an Ishikawa diagram can organize potential causes across familiar categories such as machine, method, material, measurement, people, and environment.
Use the Is/Is Not contrasts to keep brainstorming specific. Instead of listing “tooling” as a cause, ask what tooling condition could explain failures after the changeover on line A while remaining consistent with the comparison evidence.
For each hypothesis, record:
- The mechanism that could produce the observed deviation.
- Which observations it explains.
- Any observations that contradict it.
- The measurement, inspection, or controlled test needed next.
Use 5 Why to explore a supported causal path, not to turn guesses into a convincing story. If a proposed link lacks evidence, identify it as unresolved. Multiple causal branches may be necessary; there is no requirement to force every problem into exactly five questions.
Keep the definition current without losing history
The initial description will often change as evidence arrives. A defect first associated with one shift may later appear in another. A suspected material boundary may disappear when traceability improves.
Update the scope, preserve earlier versions, and explain what new evidence changed the conclusion. Keep supporting inspection reports, setup records, and applicable procedure revisions accessible through a controlled document workspace.
When the investigation establishes a previously unrecognized process risk, review the relevant process FMEA and associated controls. A clearer problem definition should support lasting process learning, not merely a better-written 8D report.
Start with a better question
Before launching another brainstorming session, check whether the team agrees on the object, deviation, timing, location, and extent. Identify relevant comparisons and mark unknowns explicitly. This small discipline helps prevent premature conclusions and directs investigation toward evidence that can distinguish competing explanations.
Try the free RCA tool without registration to start structuring your next investigation.
Explore FMEA Industry
Try FMEA Industry free for 30 days
AI-assisted FMEA, root cause analysis and operator training in one place. No card required.